SourcingAI

Box-type transformer

I have found results from100000+products and40000+suppliers aboutBox-type transformer

Commonly Used:
US$
—
Customization Available
Sample Available
Manufacturer First
Product Attributes:
Type: Combined Transformer
Type: Box Transformer
Type: Power
Type: Electromagnetic
Distribution Metering Box
Application: Power
Phase: Three
Core: Core-type Transformer
Oil-immersed Type Transformer
Winding Type: Two-winding Transformer
Certification: ISO9001-2000
Usage: Power Transformer
Frequency Characteristics: Power Frequency
Shape of Core: Ring
Operation Condition: Outdoor
Single Layer & Tightly Wound Type
Insulating Medium: Insulating Oil
Installation: Strut Type
Magnetic Circuit Structure: Combined Type
Voltage Transformation Principle: Capacitive Type
Structure: Protection
All- packaged Type
Operation Voltage: High Voltage
Size: 1 Unit
Application Range: Power Plants
Shell Material: Aluminum Alloy
Shell Protection Grade: IP56
Output Signal Type: Digital Output
Production Process: SemiConductor Integrated
Accuracy Grade: 0.1G
IP Rating: IP65
Customized: Customized
Brand: CHINT
Protection: Shock Resistance
Application: Electronic
Application: Instrument
Application: Rectifier
Application: Lighting
Switching Power Supply
Application: Audio
Phase: Single
Core: Shell-type Transformer
Cooling Method: Dry-type Transformer
Separated Winding Transformer
Winding Type: Multi-winding Transformer
Certification: ISO9001
Certification: CCC
Certification: ISO9001:2000
Certification: VDE
Certification: ISO
Usage: Distribution Transformer
Usage: Combined Transformer
Usage: Single-phase Transformer
Usage: Rectifier Transformer
Usage: Protection
Usage: Measurement
Frequency Characteristics: High Frequency
Frequency Characteristics: Low Frequency
Frequency Characteristics: Intermediate Frequency
Shape of Core: OD
Shape of Core: U
Shape of Core: EE
Shape of Core: EI
Size: 3/2 Unit
Application Range: High-rise Buildings
Shell Material: Stainless Steel
Shell Protection Grade: IP30
Shell Protection Grade: IP55

Sourcing guidance for Box-Type Transformer

What are the key technical specifications to consider when selecting a Box-Type Transformer?

Buyers must prioritize the rated capacity (kVA), voltage ratio (e.g., 10kV to 0.4kV), and cooling methods (ONAN/ONAF). Ensure the transformer core uses high-quality cold-rolled silicon steel sheets to minimize no-load losses. For the enclosure, verify the IP Rating (typically IP44 or higher) and the use of anti-corrosive materials like galvanized steel or stainless steel to withstand outdoor environmental stress.

Which international compliance standards are mandatory for global sourcing?

The product must adhere to IEC 62271-202 for high-voltage switchgear and controlgear. For specific markets, look for IEEE/ANSI standards (Americas) or CE marking (Europe). It is critical to request Type Test Reports from accredited third-party labs to verify short-circuit resistance, temperature rise limits, and insulation levels.

How do I evaluate the environmental adaptability of a prefabricated substation?

Assess the Enclosure Class based on the installation site's climate. For coastal or high-humidity areas, specify C4 or C5 corrosion resistance levels. If the unit is for high-altitude use, ensure the dielectric strength is adjusted for air density. Additionally, check for integrated fire suppression systems and automatic ventilation controls to maintain operational stability in extreme temperatures.

What are the advantages of choosing a European-style vs. American-style box transformer?

European-style (Combined) units offer better flexibility and maintainability as the high-voltage, transformer, and low-voltage components are in separate compartments. American-style (Integrated) units are more compact and cost-effective, with the transformer core and switchgear sharing the same oil tank, making them ideal for space-constrained urban residential projects.

Cross-Border Procurement Risks and Strategic Advice

How can I mitigate the risks of receiving sub-standard electrical equipment?

Always conduct a Pre-Shipment Inspection (PSI) through agencies like SGS or Intertek. Focus on dielectric tests, oil leak checks, and wiring continuity. On Made-in-China.com, prioritize Audited Suppliers who provide comprehensive factory video tours and have a proven track record of exporting heavy electrical machinery.

What are the best practices for negotiating with industrial transformer suppliers?

Negotiate based on Total Cost of Ownership (TCO) rather than just the initial purchase price. Request a detailed Bill of Materials (BOM) to see the brands of internal components (like ABB or Schneider breakers). Aim for a warranty period of at least 24 months and negotiate for 5-10% performance bond retention until the unit is successfully commissioned on-site.

What logistics precautions should be taken for shipping heavy power equipment?

Box-type transformers are heavy and sensitive to vibration. Ensure the supplier uses heavy-duty sea-worthy packaging with internal bracing. Use FR (Flat Rack) containers or Breakbulk shipping for oversized units. It is mandatory to include impact sensors (ShockWatch) on the casing to monitor mishandling during transit and ensure comprehensive cargo insurance is in place.

How do I ensure transaction security for high-value B2B electrical orders?

Utilize Secured Payment services provided by Made-in-China.com to ensure funds are only released upon milestone achievements. For large-scale infrastructure projects, consider using a Letter of Credit (L/C at sight) to protect both parties against financial and delivery risks.

Related queries