Earthing transformer
I have found results from10000+products and7000+suppliers aboutEarthing transformer
High Voltage Substation Neutral Grounding Resistor Earthing Transformer
Grounding Transformer Neutral Grounding Resistor Neutral Earthing Resistor
Hot Sale Zigzag Dry Type Earthing Transformer
100kVA Three Phase Oil Type Earthing Transformer
Customized OEM Transformer 6.3kv Earthing Dry Type Transformer
400kVA 6.3kv to 400V Earthing Dry Type Transformer Low Loss Copper Winding
20mva 30kv Earthing Oil Immersed Power Transformer
Three Phase Epoxy Resin Dry Type Earthing 250kVA 400V Class F Transformer
Three Phase Epoxy Resin Dry Type Earthing 250kVA Class F Transformer
Three Phase Nomex Insulated Dry Type Earthing 30kVA 480V Class B Transformer
1600kVA 66kv 10kv Zig Zag Earthing Transformer Oil Immersed High Voltage Neutral Grounding Station
500kVA 10kv 0.4kv Zig Zag Transformer Dry Type Cast Resin Neutral Grounding Earthing Transformer
Independent Blue Ground Stud Curus Dry Transformer, Stable Earthing Rapid Release, Custom Voltage
1250kVA 33kv Oil Immersed Earthing Transformer 50c Oil Rise 55c Winding Rise Onan Cooling
Three Phase Zigzag Grounding Transformer 11kv 200kVA with Neutral Earthing
Free Sample Earthing Sine Wave Filter 2500kVA 1000 kVA High Frequency Transformer
Free Sample 220V to 380V Step up Machine Earthing Sine Wave Filter High Frequency Transformer
33 Kv Zn Grounding and 34.5 Kv Earthing Pad Mounted Transformer
Electrical 33 34.5 Kv Padmount Substation Earthing Zn Grounding Transformer
Customized Dry Type Power Transformer with Dyn11 Neutral Earthing
Transformer Earthing Terminal with Corrosion Resistant Surface Finish
Zig Zag Connected Grounding Transformer for Neutral Earthing
Ground Monitoring Oil Immersed Transformer Ensures Reliable Earthing Connection
CCC Certified 25kv Oil Immersed Transformer as Energy Earthing Transformer for Wind Power Farm
Oil Cooled 1600kVA Oil Immersed Transformer as Rugged Earthing Transformer for Water Treatment Plant
Sourcing guidance for Earthing Transformer
What are the key technical specifications to evaluate when sourcing an Earthing Transformer?
Buyers must prioritize the Short-Time Current Rating (A) and Duration (seconds), typically 10s or 30s, to ensure the unit survives fault conditions. Additionally, verify the Zero-Sequence Impedance, which is critical for limiting fault current. For ZN (Zigzag) connections, ensure the Insulation Class (Class A, F, or H) matches the environmental temperature of the installation site.
Which international compliance standards are mandatory for these products?
Ensure the supplier adheres to IEC 60076-6 (Reactors) or IEEE C57.12.00 standards. For European markets, CE marking and EcoDesign Directive compliance are essential. If the transformer is oil-filled, verify that the oil meets IEC 60296 specifications for mineral insulating oils.
How do I choose between a Zigzag (ZN) and a Star-Delta (YNd) configuration?
Zigzag (ZN) transformers are generally more cost-effective and space-efficient for providing a neutral point because they do not require a secondary winding. However, Star-Delta (YNd) transformers are preferred if a secondary auxiliary load (like station power) is required simultaneously with the grounding function.
What cooling methods are most suitable for industrial earthing applications?
For outdoor substations, ONAN (Oil Natural Air Natural) is the industry standard due to its reliability and low maintenance. For indoor or high-fire-risk environments, Cast Resin (Dry-type) transformers are recommended, though they require higher initial investment and strict IP23 or higher enclosures.
Cross-Border Procurement Strategy for High-Voltage Equipment
How can I mitigate the risk of damage during international transit?
Request vacuum-sealed packaging and the use of Impact Recorders (G-force sensors) on the crates. For oil-filled units, specify that they must be shipped with a positive pressure of dry nitrogen or fully filled with oil to prevent moisture ingress. Ensure the supplier provides seaworthy wooden cases compliant with ISPM 15.
What are the best practices for negotiating with Chinese electrical manufacturers?
Focus on the Copper vs. Aluminum winding price difference; always specify 100% electrolytic copper to ensure longevity. Use Made-in-China.com's Secured Trading services to escrow payments until the Factory Acceptance Test (FAT) report is uploaded and verified by a third-party inspector like SGS or Intertek.
How do I handle customs and logistics for heavy industrial machinery?
Confirm the HS Code (typically 850433/850434) with your broker to check for anti-dumping duties. Given the weight, use FOB (Free On Board) terms to maintain control over the sea freight carrier, and ensure the supplier provides a Certificate of Origin to leverage potential Free Trade Agreements (FTA) for duty reduction.
What transaction security measures should be taken for high-value transformer orders?
Never transfer full payment upfront. Follow a 30-40-30 payment structure: 30% deposit, 40% after successful Routine Tests (Dielectric, Resistance, and Ratio tests), and the final 30% against the Bill of Lading. Always conduct a Video Audit of the factory via Made-in-China.com to verify production capacity.