SourcingAI

Electric alternator

I have found results from200000+products and70000+suppliers aboutElectric alternator

Commonly Used:
US$
—
Customization Available
Sample Available
Manufacturer First
Product Attributes:
Basic Diesel Generator
Self-Starting Diesel Generator
Type: Head Cover
Type: Rotator
Installation Method: Fixed
Cooling Method: Water Cooling
AC Three Phase
Speed: Speed
Conditions of Use: Land Use
Landuse Type of Unit: Ordinary
AC Rotating Exciter
Silicon Rectification Generator
Rectifier Structure: Six Tubes
Current Level: 9(≥90A)
Bonding Type of Magnetic Field Winding: Outer Bonding
Brushless Alternator Type: Claw-pole Type
Voltage Adjuster Type: Electromagnetic Vibratory
Head Cover Position: Front
Stroke: Four Stroke
Usage: Common Units
Conditions of Use: Marine
Cooling Method: Water Cooling
Installation Method: Fixed
Generator Type: Diesel Generator
Voltage: 24V
Brand: Cummins
Application: Industrial
Number of Stator: Three-Phase
Function: Driving
Casing Protection: Protection Type
Direct on-line Starting
Certification: ISO9001
Standard Component: Standard Component
Technics: Press
Material: Iron
Control System: Electromagnetic-Operated
Rotation Direction: Counter-clockwise Rotation
Installation Method: Portable
Cooling Method: Air Cooled
Cooling Method: Wind Cooling
AC Single Phase
Speed: 1500rpm
Speed: 1800rpm
Speed: 750rpm
Speed: 3000rpm
Speed: 3600rpm
Conditions of Use: Car Type
Low Noise Automation Type
Landuse Type of Unit: Low Noise
Excitation Mode: Static Exciter
Structure: Brushless Alternator
Structure: Magneto Alternator
Structure: Integral Alternator
Rectifier Structure: Eleven Tubes
Current Level: 5(50~59A)
Current Level: 2(20~29A)
Bonding Type of Magnetic Field Winding: Inner Bonding
Permanent Magnet Type
Brushless Alternator Type: Magnetizing Type
Voltage Adjuster Type: Electronical
Head Cover Position: Back
Stroke: Two Stroke
Usage: Standby Unit
Usage: Emergency Crew
Conditions of Use: Land Use
Installation Method: Portable
Voltage: 12V
Function: Control
Technics: Casting

Sourcing guidance for Electric Alternator

How to choose the right Electric Alternator for industrial or commercial use?

Selecting an electric alternator requires a precise match between the power source and the load requirements. Buyers must prioritize Brushless Excitation systems for reduced maintenance and higher reliability. Key technical factors include the KVA/kW rating, ensuring it handles both continuous load and peak starting currents. For industrial environments, look for an IP23 protection rating or higher to guard against moisture and dust, and ensure the unit features a high-quality Automatic Voltage Regulator (AVR) to maintain voltage stability within ±1%.

What are the critical compliance and quality standards for alternators?

To ensure safety and international market access, alternators must comply with IEC 60034-1 (Rotating electrical machines) and ISO 8528 standards. For the North American market, UL or CSA certification is essential, while CE marking is mandatory for Europe. Verify that the manufacturer uses Class H insulation, which allows for higher temperature rises (up to 125°C above ambient) without degrading the copper windings, significantly extending the machine's lifespan.

How can buyers evaluate the technical performance of a supplier's alternator?

Request a Type Test Report or a factory acceptance test (FAT) record. Focus on the Total Harmonic Distortion (THD); for sensitive electronic equipment, the THD should be less than 5% at no load. Additionally, check the winding pitch—a 2/3 pitch design is preferred as it eliminates the third harmonic on the voltage waveform, making it safer for parallel operation with other generators or the utility grid.

What maintenance and after-sales factors should be considered?

Evaluate the bearing life (L10 life), which should ideally exceed 20,000 to 40,000 hours. Ensure the supplier provides a comprehensive spare parts kit (including diodes, varistors, and AVRs) and offers a warranty of at least 12 to 24 months. For large-scale procurement, prioritize suppliers on Made-in-China.com who offer technical remote support or have localized service centers to minimize downtime during critical failures.

Cross-Border Procurement Risks and Strategies for Alternators

What are the common risks when purchasing alternators internationally?

The primary risks include shipping damage to heavy rotors and specification mismatch (e.g., 50Hz vs. 60Hz). To mitigate this, insist on seaworthy vacuum packaging with anti-rust coating and moisture-absorbent silica gel. Always confirm the frequency and phase requirements (Single-phase vs. Three-phase) in writing before production begins to avoid receiving unusable equipment.

How should buyers negotiate with Chinese alternator manufacturers?

Focus on the copper content and purity rather than just the final price. Some low-cost suppliers may use copper-clad aluminum (CCA) instead of 100% pure electrolytic copper. Negotiate for Tiered Pricing based on annual volume and request Trade Assurance through platforms like Made-in-China.com to secure your payment until the goods pass third-party inspection.

What are the best practices for shipping and logistics for heavy electrical machinery?

Alternators are heavy and sensitive to vibration. Use FOB (Free On Board) terms to maintain control over the freight forwarder selection. Ensure the units are bolted to reinforced fumigated wooden pallets or steel frames. For high-value orders, it is highly recommended to purchase Marine Cargo Insurance covering 'All Risks' to protect against potential transit damage or loss.

How to ensure transaction security and supplier legitimacy?

Conduct a Factory Audit or hire a third-party inspector (like SGS or Intertek) to verify the production line. Check the supplier's Business License and Export Qualifications on Made-in-China.com. Look for 'Audited Suppliers' who have undergone rigorous on-site verification to ensure they have the R&D capability and testing equipment necessary for high-voltage machinery.

Related queries