Electric generator
I have found results from200000+products and70000+suppliers aboutElectric generator
Yuchai 200kVA 400kVA 500kVA Genset Emergency Marine Three Phase Electric Silent Diesel Power Generator
High Quality Electric Power Generator 100kw-500kw by Ricardo Engine
Container Engine 2000kw Huaquan Diesel Genset Heavy Duty Diesel Generator Electric Power Container Generation
Electric Start Emergency Silent Soundproof Diesel Generator 12.8kw to 1000kw Powered by Weichai Engines Power Generator
50kVA100kVA 200kVA 250kVA 300kVA 500kVA 1000kVA Cummins Silent Electric Diesel Generator
Silent Electric Portable Open Type Water Cooled Marine Cummins Perkins Diesel Generator with Stanford Alternator
Newland 2kw 3kw 4kw 5kw 6kw 7kw 8kw 10kw Elemax Electric Home Power Silent Petrol Portable Gasoline Generator
Weichai Baudouin Diesel Generator 150 Kw Generator Big Power Electric
3 Phase Yanmar Ricardo Fawde Electric Generator for Weichai Cummins Perkins with Industrial Use
15kVA 20kVA 30kVA 50 kVA Electric Silent Diesel Generators 15kw 20kw 30 Kw 3 Phase Power Generator Diesel
Powered by Kta38-G4 Soundproof Type 800kw 480V 60Hz Diesel Generator 1250kVA Electric Genset with Stamfords Alternator
CE Approved 400kw Weichai Natural Electric Gas Engine Generator Fo Power Generation
High Quality China Portable Yatong Customized Engine Silent Electric Trailer Diesel Generator
Bison Electric Mini Portable Gasoline/Petrol 2kw 3kw Quiet Home Inverter Generator
Senwei Sv5200e2 4-Stroke Air-Cooled Mobile Portable Electric Start 2.5kw Homeuse Gasoline/Petrol Generator
Customization 100-1000kw Electric Power Soundproof Silent Container Diesel Engine Generator Set
Sourcing guidance for Electric Generator
How do I determine the correct power capacity for my procurement needs?
Buyers must distinguish between Starting Watts (Surge) and Running Watts (Rated). For industrial equipment with motors, the starting power can be 3 to 5 times higher than the running power. It is recommended to calculate the total load and add a 20% safety margin to prevent alternator overheat and ensure long-term reliability.
What are the key differences between Diesel, Gasoline, and Inverter generators?
Diesel generators are the gold standard for heavy-duty industrial use due to their fuel efficiency and longevity. Gasoline units are more portable and have a lower initial purchase cost, making them ideal for light construction. Inverter generators provide 'clean' sine wave power (THD <3%), which is essential for protecting sensitive electronics like servers and medical devices.
What international compliance standards should I verify before purchasing?
For the US market, ensure EPA or CARB certification for emissions. For the EU, CE marking and Stage V emission standards are mandatory. Additionally, look for ISO 8528 (Reciprocating internal combustion engine driven alternating current generating sets) to ensure the unit meets global performance and safety benchmarks.
What cooling and enclosure specifications are critical for outdoor use?
For high-temperature environments, prioritize water-cooled engines over air-cooled ones. If the generator is used in residential or office areas, specify a Silent Canopy (Soundproof Enclosure) that reduces noise levels to below 70dB at 7 meters. Ensure the enclosure has an IP23 rating or higher for moisture and dust protection.
Cross-Border Procurement Strategy for Electric Generators
How can I mitigate the risk of receiving substandard mechanical components?
Always request a Factory Acceptance Test (FAT) report and a video of the load bank test (running the generator at 25%, 50%, 75%, and 100% load). For large orders, hire a third-party inspector to verify the copper winding quality of the alternator, as cheaper aluminum windings significantly reduce lifespan.
What are the logistics considerations for shipping large power equipment?
Generators are classified as Dangerous Goods (Class 9) if they contain fuel or batteries. Ensure the supplier provides a Material Safety Data Sheet (MSDS) and a UN38.3 test report for batteries. Use FOB terms to maintain control over freight costs, and ensure the unit is secured in a fumigated wooden crate to prevent structural damage during sea transit.
How should I negotiate after-sales support for technical machinery?
Since returning a heavy generator is economically unfeasible, negotiate for 1-2% free-of-charge (FOC) wearing parts (filters, belts, gaskets) to be included in the container. Ensure the contract specifies remote technical support response within 24 hours and verify if the engine brand (e.g., Cummins, Perkins, or local brands) has a global service network in your destination country.
How do I ensure transaction security when dealing with high-value industrial orders?
Utilize secure payment methods and consider sourcing through reputable platforms like Made-in-China.com, which offers trade security services to protect your deposit. Avoid 100% upfront payments; a standard 30% deposit and 70% balance against the Bill of Lading (B/L) is the industry norm for verified suppliers.





























