SourcingAI

Elevator ups

I have found results from30000+products and10000+suppliers aboutElevator ups

Commonly Used:
US$
—
Customization Available
Sample Available
Manufacturer First
Product Attributes:
Type: On-line
Type: Line Interactive
Phase: Three Phase
Protection: Overvoltage
Application: Communication
Classification: Lighting/Power
Standby Time: Long-acting Machine
Sine Wave Output UPS
Output Capacity: Medium Type
Equipment Mode: Decentralized
Brand: Emerson
Gear and Rack Elevator
Capacity: 500-1000kg
6 - 10
1.00 - 2.00m/s
Control Mode: Group Control
Position of Computer Room: up
Center Opening Door
Door Knife: Single
With Deceleration Device
Attendant: Without Attendant
Phase: Single Phase
Protection: Short Circuit
Sealed Maintenance Free
Protection: Unbalanced Loads
Protection: Overcurrent
Application: Industry
Application: Defence
Application: Fire Safety
Classification: Lighting
Standby Time: Standard Machine
Square Wave Output UPS
Output Capacity: Large Type
Equipment Mode: Centralized Model

Sourcing guidance for Elevator Ups

What are the key technical specifications to consider when sourcing an Elevator UPS?

When selecting an Elevator UPS, the most critical factor is the Automatic Rescue Device (ARD) functionality. You must ensure the output waveform is a Pure Sine Wave to protect sensitive elevator control boards. The rated power (kVA/kW) should be at least 1.25 to 1.5 times the motor's peak load to handle high starting currents. Additionally, verify the battery backup duration, which typically ranges from 15 to 30 minutes, sufficient for emergency leveling and door opening.

Which international compliance standards are mandatory for Elevator UPS systems?

Safety is paramount in vertical transportation. Ensure the product complies with EN 81-20/50 (European elevator safety standards) or ASME A17.1 (North American standards). For electrical safety, look for CE, RoHS, and ISO 9001 certifications. If you are sourcing for the US market, UL 1778 (UPS equipment) and UL 924 (Emergency Lighting and Power Equipment) are often required by local building codes.

How does the environment affect the performance and lifespan of an Elevator UPS?

Elevator machine rooms often experience high temperatures and dust. You should prioritize units with an IP20 or higher protection rating and intelligent cooling systems. The operating temperature range should ideally be 0°C to 40°C. For humid climates, ensure the internal PCBs have conformal coating to prevent corrosion and short circuits, extending the service life to the industry standard of 5–8 years.

What integration capabilities should a modern Elevator UPS offer?

B2B buyers should look for units equipped with RS485 or SNMP communication ports. This allows the UPS to integrate with the Elevator Management System (EMS) or Building Management System (BMS) for real-time monitoring of battery health and power status. Dry contact signals are also essential for triggering the elevator controller's emergency mode immediately upon grid failure.

Cross-Border Procurement & Risk Management for Elevator UPS

What are the primary risks when shipping Elevator UPS systems internationally?

The main risk involves the Lead-Acid or Lithium batteries, which are classified as Dangerous Goods (Class 9). You must ensure the supplier provides a valid MSDS (Material Safety Data Sheet) and UN38.3 test report. To mitigate damage, request reinforced wooden crate packaging and use sea freight for bulk orders to maintain cost-efficiency, as air freight for heavy batteries is prohibitively expensive.

How can I verify the reliability of a supplier on Made-in-China.com?

Focus on Audited Suppliers who have undergone on-site inspections by third-party agencies like SGS or Intertek. Check their Export Experience—suppliers who have successfully exported to your target region will be more familiar with local voltage requirements (e.g., 380V/400V/415V three-phase) and customs documentation. Always request a factory video audit or a third-party pre-shipment inspection (PSI).

What negotiation strategies should be used for bulk Elevator UPS orders?

Negotiate based on Total Cost of Ownership (TCO) rather than just the unit price. Ask for a 2-3% spare parts kit (including cooling fans and control fuses) to be included in the initial price. For orders exceeding 50 units, aim for a 10-15% volume discount and negotiate for a 24-month extended warranty to provide better value to your end-users.

How do I ensure transaction security and quality assurance?

Utilize Secured Trading services offered on Made-in-China.com to protect your payment until shipping is confirmed. Define a clear Quality Agreement in the contract that specifies the battery brand (e.g., Yuasa, Panasonic, or reputable local brands) and the inverter efficiency (≥90%). Never release the final 20-30% payment until the Bill of Lading (B/L) is issued and the inspection report is approved.

Related queries