SourcingAI

Emergency panel light

I have found results from100000+products and60000+suppliers aboutEmergency panel light

Commonly Used:
US$
—
Customization Available
Sample Available
Manufacturer First
Product Attributes:
Type: Ceiling
Type: Recessed
Light Source: Sodium Lamp
Light Type: Solar
Color Temperature: Warm White
Power: 21W-30W
Technics: Chrome-plating
Illumination Time: 6h
Usage: Garden
IP Rating: IP55
With Light Source
Lamp Body Material: Plastic
Cell Type: Ni-MH Battery
Charging Time (H): 8
Certification: CE
Voltage: 3-6V
Crust Color: Green
Bulb Type: LED
Emitting Color: Red
Housing Material: Acrylic
Dimmable: With Dimmable
Appearance: Square
Base Material: Plastic
Beam Angle: 120°
Projection Distance: 18-25m
Application: Park
LED Chips Brand: Epistar
Input Voltage: 90V-260V
Color: White
LED Type: SMD 3528
Battery Type: Lead-acid
Style: Countryside
Warranty Period: 2 Years
15-30 Square Meters
Material: Aluminum
Applicable Places: Conference Room
Brightness Level: 2,000-5,000 Lumens
Mount Type: Surface
Source Number: Single Plug
Installation: Recessed
Lamp Installation: Plug Lamp
Touch On/Off Switch
Warranty: 3 Years
Shape: Square
Shade Type: Plastic
Install Style: Suspended
Light Range: <50m
Lighting Period (H): 4
Power Supply: Rechargeable Battery
Light Source: LED Lamp
Light Source: LED
Light Source: Energy-saving Lamps
Light Type: LED
Color Temperature: Cool White
Power: ≥30W
Power: ≤5W
Power: 11W-15W
Technics: Electroplating
Technics: Painted Matte
Illumination Time: 8h
Illumination Time: 10h
Illumination Time: 12h
Usage: Street
Usage: Room
Usage: Study
Usage: Restaurant
Usage: Aisle
Usage: living room
Usage: balcony
Usage: TOILET
Usage: Kitchen
Usage: Conference Room
IP Rating: IP67
IP Rating: IP33
IP Rating: IP65
IP Rating: IP44
Lamp Body Material: Aluminum
Lamp Body Material: Metal
Lamp Body Material: Iron
Charging Time (H): 4
Charging Time (H): 10
Certification: RoHS
Certification: CCC
Certification: Reach
Certification: SAA
Certification: GS
Certification: ISO
Certification: FCC
Certification: ISO9001
Certification: CQC
Certification: C-tick
Certification: EMC
Certification: Energy Star
Certification: ETL
Certification: FDA
Certification: GOST
Certification: LVD
Certification: PSE
Certification: REACH
Certification: SASO
Certification: VDE
Voltage: 120V
Voltage: 100-240V
Voltage: 220V
Voltage: 12/24V
Voltage: 12V
Voltage: 90V-260V
Voltage: 240V
Emitting Color: White
Emitting Color: RGB
Emitting Color: Yellow
Housing Material: Aluminium
Beam Angle: 60°
Application: Square
Application: Factory
Application: Engineering
Application: Home Furnishing
Input Voltage: 110V
Battery Type: Ni-Cd
Style: Contemporary
Style: modern
Material: ABS

Sourcing guidance for Emergency Panel Light

What are the key technical specifications to consider when sourcing Emergency Panel Lights?

Buyers should prioritize high-efficiency LED chips (minimum 100lm/W) and lithium iron phosphate (LiFePO4) batteries, which offer longer lifecycles and better thermal stability than traditional Ni-Cd batteries. Ensure the emergency duration is at least 90 to 180 minutes depending on local fire safety codes. Additionally, look for integrated self-test functions that automatically perform monthly and annual checks to ensure operational readiness.

Which compliance standards and certifications are mandatory for international markets?

For the European market, CE-LVD, CE-EMC, and RoHS are essential, along with EN 60598-2-22, which specifically governs emergency lighting requirements. For the North American market, UL 924 (Emergency Lighting and Power Equipment) is the gold standard. Ensure the supplier provides valid test reports from accredited third-party labs like TUV, SGS, or Intertek to avoid customs clearance issues.

How does the 'Switching Time' affect the performance of the emergency light?

The switching time (transfer time) should ideally be less than 0.5 to 1 second. In critical environments like hospitals or high-traffic commercial zones, a rapid transition from mains power to battery power is vital for safety. Verify that the driver is compatible with both constant current output and emergency modules to prevent flickering during the switch.

What are the common usage scenarios and installation requirements for these products?

Emergency panel lights are primarily used in office buildings, hospitals, schools, and shopping malls. Buyers must choose between recessed, surface-mounted, or suspended installations based on the ceiling type. For high-humidity areas like underground parking lots, ensure the product has an IP44 or higher ingress protection rating to prevent moisture damage to the internal circuitry.

Cross-Border Procurement Risks and Strategies

How can I mitigate the risk of battery degradation during long-distance shipping?

Batteries are sensitive to temperature and time. Require the supplier to use freshly manufactured battery cells (less than 3 months old) and ensure they are charged to 30-50% before shipping. Request UN38.3 certification and MSDS reports to comply with international air and sea freight regulations for hazardous materials.

What is the best strategy for negotiating with suppliers on Made-in-China.com?

Focus on Total Cost of Ownership (TCO) rather than just the unit price. Negotiate for extended warranties (3-5 years) on the emergency driver and battery, as these are the most common failure points. For bulk orders, ask for 1-2% spare parts (FOC) to be included in the shipment to handle immediate replacements for minor defects.

How do I ensure transaction security and quality control before final payment?

Utilize Secured Trading Services provided by Made-in-China.com to protect your funds. Always hire a third-party inspection agency to conduct a Pre-Shipment Inspection (PSI). The inspector should specifically test the emergency function by cutting the power and measuring the light output and duration to ensure it matches the agreed-upon specifications.

What shipping methods are recommended for electronic products containing batteries?

For large volumes, Sea Freight (FCL/LCL) is the most economical, but you must ensure the carrier accepts Class 9 dangerous goods if the batteries are integrated. For urgent samples, use specialized couriers (like DG-certified lines). Always ensure the packaging includes anti-static materials and robust outer cartons to prevent physical damage during transit.

Related queries