Prosthetic hand
I have found results from1000+products and600+suppliers aboutProsthetic hand
Silicone Prosthetic Artificial Limb Silicone Cosmetic Hand Artificial Prosthetic Hand
Prosthetic Hand Orthopedic Implants Medical Prosthetics Silicone Hand Cover Artificial Hand
Myoelectric Prosthesis Forearm Prosthetic Arm, Prosthetic Hands
Hot Sale Myoelectric Prosthesis Forearm Prosthetic Arm Prosthetic Hand
Medical Prosthetic Hand Myoelectric Hand with Two Degrees of Freedom for Be
Prosthetic Hand Myoelectric Control with Two Degrees of Freedom for Ae
Cosmetic Skeleton Hand with Adapter Connector Prosthetic Hand
Prosthetic Limbs Artificial Hand Orthopedic Implants Artificial Prosthetic Silicone Hand
Artificial Limbs Myoelectric Ae Hand with Three Degrees of Freedom Prosthetic Hand
Prosthetic Limbs Myoelectric Control with Three Degrees of Freedom Prosthetic Hand for Ae
Prosthetic Hands Cable Control Mechanical Prosthesis Forearm Prosthetic Hand
Prosthetics Artificial Hands Cable Control Mechanical Prostheses Prosthetic Hand
High Quality Cable Above Elbow Shell Prosthetic Limb Hand
Advanced Artificial Limb Orthotic Medical Limb Prosthetic Myo Hand for Amputee
Ai Robot Bionic Prosthetic Hand Standard Fitting Artificial Limb (Forearm)
Ai Robot Intelligent Bionic Prosthetic Hand Smart Arm
Advanced Upper Limbs Bionic Arm Prosthetic Hand for Enhanced Mobility
Advanced Robotic Prosthetic Hand with Artificial Intelligence Technology
Intelligent Bionic Hand Sensor Prosthesis Prosthetic Hand for Adult and Children
Prosthetic Upper Limbs Cable Control Hand Prosthesis
Artificial Limbs Prosthetic Hand, Cable Controlled Mechanical Hand
Artificial Limbs Myoelectric Arm Prostheses Arm Prosthetic Hand for Amputee
Artificial Arm Prosthetic Arm Myoelectric Arm Prostheses Artificial Limbs Hand
Artificial Arm Sjq11 Myoelectric Hand Arm Prostheses Prosthetic Hand
Sourcing guidance for Prosthetic Hand
What are the key technical specifications to consider when sourcing prosthetic hands?
Buyers should prioritize degrees of freedom (DoF), which determine the hand's dexterity, and grip force, typically ranging from 15N to 100N depending on the model. Ensure the device uses high-strength materials like medical-grade silicone, carbon fiber, or aircraft-grade aluminum for a balance of durability and lightweight performance. For myoelectric versions, verify the signal processing speed (latency should be <100ms) and battery life, aiming for at least 12-16 hours of active use.
What international compliance standards are mandatory for prosthetic devices?
As medical devices, prosthetic hands must adhere to strict regulatory frameworks. Ensure the supplier holds ISO 13485 (Medical Devices Quality Management Systems). For the US market, FDA Class I or II registration is required; for the EU, CE marking under the Medical Device Regulation (MDR 2017/745) is essential. Additionally, check for IEC 60601-1 compliance regarding the electrical safety of active medical devices.
How do I evaluate the functional suitability for different user scenarios?
Distinguish between passive (cosmetic), body-powered, and myoelectric (bionic) hands. For high-activity users, focus on waterproof or water-resistant ratings (IP67 or higher) and impact resistance. For office or daily tasks, prioritize multi-grip patterns (e.g., tripod, pinch, power grip) and touchscreen compatibility on the fingertips.
What integration and customization capabilities should a professional supplier offer?
A top-tier supplier should provide customizable socket interfaces and adjustable wrist connectors (e.g., 1/2-20 thread or Quick Disconnect systems). Verify if they offer software for clinicians to calibrate muscle sensors and if they provide various skin-tone silicone gloves to meet aesthetic requirements for end-users.
Cross-Border Procurement Strategy & Risk Management
How can I mitigate quality risks when purchasing medical prosthetics from overseas?
Always request a pre-shipment inspection (PSI) by a third-party agency like SGS or Intertek. Specifically, ask for a cycle test report (e.g., 100,000 open/close cycles) to ensure mechanical longevity. Use Made-in-China.com's Secured Trading services to ensure payment is only released after the goods pass quality verification.
What are the best practices for negotiating with prosthetic manufacturers?
Focus on long-term technical support rather than just the unit price. Negotiate for a warranty period of at least 24 months and the inclusion of spare parts kits (cables, sensors, gloves) in the initial bulk order. For large volumes, aim for a 15-20% discount compared to sample pricing.
What shipping precautions are necessary for sensitive electronic prosthetics?
Prosthetic hands contain sensitive sensors and often Lithium-ion batteries, which are classified as Dangerous Goods (UN3481). Ensure the supplier provides a Material Safety Data Sheet (MSDS) and uses anti-static, shock-absorbent packaging. For international transit, Air Freight is recommended over Sea Freight to minimize exposure to humidity and prolonged vibration.
How do I handle customs clearance for medical devices?
Ensure all documentation includes the correct HS Code (typically 9021.39). You must provide the Declaration of Conformity, Commercial Invoice, and Packing List that clearly states the medical registration numbers. Failure to provide a valid import license for medical devices in your destination country can lead to seizure by customs.

























